UniPulse 400
412A910

UniPulse 400

An easy to use defibrillator analyzer with pacer

- Compact, rugged design with large color screen
- Compatible with monophasic, biphasic and pulsed waveforms
- Rechargeable battery allowing operation without the need for mains power
- ECG simulation with high level output
- Reliable and non-inductive defibrillator test load of 50Ω

Available in the US - Call 813 886 2775


Compact, Rugged Design
A comprehensive defibrillator/pacer analyzer that fits in your hand
ECG and Pacer Simulations
Over 40 selectable arrhythmias and 5 pacer modes
Colour LCD Display
Clear and vibrant display with simple navigation – including dedicated fast keys
Full Compatibility
Accurately measure and display waveforms from monophasic to biphasic

More about the UniPulse 400

The UniPulse 400 is designed to comprehensively test all defibrillators accurately and efficiently. The large vibrant colour screen will display both test results and waveforms in amazing detail. The dedicated fast keys and simple to use operating system enables test engineers to select the relevant test function in seconds.

This comprehensive defibrillator analyzer is capable of analyzing all monophasic, biphasic, standard and pulsating waveforms. This unrivalled functionality and our new comprehensive pacer function makes the UniPulse 400 the ultimate defibrillator analyzer on the market.

The large internal memory and on-board results storage will reduce test time and help work towards a modern paperless system. Download results to "Med-eBase" asset management software via our simple USB function or use the on screen data recall to review results – it's never been so simple.

The ergonomic enclosure of the UniPulse 400 makes the unit compact, rugged and lightweight so you can easily move location with this portable product. Our handy Rigel carry case can fit the unit alongside any additional accessories you may require allowing easy transportation to different sites.

These are just a few of the reasons we believe you'll want to invest in our UniPulse 400. To see for yourself, request a live online demonstration today!

Why buy the UniPulse 400?

> The complete defibrillator analyzer solution – including pacer functionality.

> Clear and vibrant LCD colour display with simple navigation – including dedicated fast keys. Less button pushing, more testing.

> Rugged, compact and easy to hold – take it anywhere, anytime... easily with battery operation.

> Compatible with all defibrillators – accurately measure and display waveforms from monophasic to biphasic, all in a tester that fits in your hand.

UniPulse 400 Demonstration Video:

Key Features

- Pacer functionality

- Compatible with monophasic, biphasic and pulsed waveforms

- Colour LCD display

- Easy and intuitive navigation with dedicated fast test and simulation keys

- Rechargeable battery allowing operation without the need for mains power

- Data download via USB to PC

- Reliable and non-inductive defibrillator test load of 50Ω

- Variable pacer load 50Ω to 1600Ω in 50Ω steps

- ECG simulation with hi-level output

- Multi-lingual firmware to meet requirements across the globe

- Portable, compact and rugged

- Robust carry case to protect your analyzer

Simulation Functions

- Defibrillator energy discharge

- Charge time

- Cardiac synchronisation

- Over 40 selectable arrhythmias

- Performance waveforms

- 5 pacer modes


Request a Quote


Optional Accessories

Technical Specifications

Defib - Energy Measurement
Load Resistance50Ω ± 1% non-inductive
Range0 - 199.9 Joules
Accuracy± 1% of reading ± 1 Joule
Range (High)200 - 600 Joules
Resolution0.1 Joules
Voltage0 - 5000 Volts
Current0 - 100 Amps
Maximum pulse width5μs – 120ms
ECG Simulator
ECG simulation with hi-level output.
ECG Waveforms – Ventricular Arrhythmias
Premature Ventricular Contraction - Intermittent 80 BPM, Amplitude 0.50 - 5.00mV(±2%)Default Spec Value
(PVCI)
Bigeminy (BIG)80 BPM, Amplitude 0.50 - 5.00mV(±2%)
Trigeminy (TRIG)80 BPM, Amplitude 0.50 - 5.00mV(±2%)
Ventricular Flutter (VFLT)240 BPM, Amplitude 0.50 - 5.00mV(±2%)
Ventricular Fibrillation - Coarse (VFBC)240 BPM, Amplitude 0.50 - 5.00mV(±2%)
Ventricular Fibrillation - Fine (VFBF)240 BPM, Amplitude 0.50 - 5.00mV(±2%)
Monomorphic Ventricular Tachycardia (MVT)210 BPM, Amplitude 0.50 - 5.00mV(±2%)
Right-focal Premature Ventricular Contraction80 BPM, Amplitude 0.50 - 5.00mV(±2%)
ECG Waveforms – Atrial Arrhythmias
Sinus Arrhythmia (SAR)20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%)
Missing Beat (MB)20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%)
Atrial Flutter (AFLT)300 BPM, Amplitude 0.50 - 5.00mV(±2%)
Atrial Fibrillation (AFB)20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%)
Paroxysmal Atrial Tachycardia (PAT)180 BPM, Amplitude 0.50 - 5.00mV(±2%)
Premature Junctional Contraction (PJC)20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%)
ECG Performance Waveforms
Sine (SINE)0.1 - 300Hz, 1.00 – 10.00mV
Square (SQ)0.1 - 300Hz, 1.00 – 10.00mV
Triangle (TRI)0.1 - 300Hz, 1.00 – 10.00mV
Sawtooth (SAW)0.1 - 300Hz, 1.00 – 10.00mV
Inverse Sawtooth (INVSAW)0.1 - 300Hz, 1.00 – 10.00mV
Pulse (PULSE)0.1 - 300Hz, 0.50 – 5.00mV
ECG Waveform Output
Low LevelLow Level
Hi LevelOutput Jack
Pacer Input
Fix Load50Ω
Accuracy+/- 4% + 10µJ
Over voltage protection5000V
Variable Load50 to 1600Ω in 50Ω steps
Pulse Rate5.0 to 800 ppm
Heart rate selection20 – 300 bpm
Under & overdrive85% (20 bpm min) and 115% (300 bpm max)
Wave form selectionNSR, VFibC, VFibF, MVT, AFib, Missing Beat, R-Wave detection
Pulse Current Amplitude5.00 – 200mA
Accuracy +/-(1% rdg +0.02mA)
Current MeasurementsAverage (RMS), Leading edge, Trailing edge, Peak (the highest during the pulse)
Pulse Width1.00 - 100ms
Pulse Energy1µJ – 2.00J
Pacer Refractory Periods
Refractory Period test15 – 500mS (Paced and sensed)
Accuracy+/- 1ms
Pacer Interference Test (Immunity)
Heart rate20-300 bpm
Frequency50 or 60 Hz
Noise level in mV0-15.0mV
AED Pulse Mode Waveforms
Normal Sinus Rhythm (NSR)20 - 300 BPM, Amplitude 1.00mV(±2%)
Asystole (ASYS)
Ventricular Fibrillation - Coarse (VFBC)240 BPM, Amplitude 1.00mV(±2%)
Ventricular Fibrillation - Fine (VFBF)240 BPM, Amplitude 1.00mV(±2%)
Monomorphic Ventricular Tachycardia (MVT)210 BPM, Amplitude 1.00mV(±2%)
Atrial Fibrillation (AFB)20 - 300 BPM, Amplitude 1.00mV(±2%)
ECG Waveforms - Sinus
Normal Sinus Rhythm (NSR)20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%)
ST Elevation (STE)20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%)
ST Depression (STD)20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%)
Myocardial Infarction (MI)20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%)
Tall T (TT)20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%)
Asystole (ASYS)
ECG Waveforms – Atrial Conduction Arrhythmias
First Degree AV Bock (FAVB)80 BPM, Amplitude 0.50 - 5.00mV(±2%)
Second Degree AV Block - Mobitz I (SAVB_MI)80 BPM, Amplitude 0.50 - 5.00mV(±2%)
Second Degree AV Block - Mobitz II (SAVB_MII)80 BPM, Amplitude 0.50 - 5.00mV(±2%)
Third Degree AV Block (TAVB)50 BPM, Amplitude 0.50 - 5.00mV(±2%)
ECG Pacer Waveforms
Synchronous Atrial (AAI)20 - 300 BPM, Pulse amplitude 0.50 – 5.00mV, Pulse width 0.1 – 2.0ms
Asynchronous Atrial (AOO)20 - 300 BPM, Pulse amplitude 0.50 – 5.00mV, Pulse width 0.1 – 2.0ms
Pacer (PCR)20 - 300 BPM, Pulse amplitude 0.50 – 5.00mV, Pulse width 0.1 – 2.0ms
Ventricular Pacer (VVI)20 - 300 BPM, Pulse amplitude 0.50 – 5.00mV, Pulse width 0.1 – 2.0ms
Atrial & Ventricular Pacer (DDD)20 - 300 BPM, Pulse amplitude 0.50 – 5.00mV, Pulse width 0.1 – 2.0ms
R-Wave Detection (RWD)20 - 300 BPM, Pulse amplitude 0.50 – 5.00mV
ECG Noise Selection
AmplitudeDefault Spec Value0 – 10.00mV
Frequency50 - 60Hz
ECG Accuracy
RateDefault Spec Value± 1%
Amplitude± 2% (LA-LL), ± 10% (Paddles)
Lead II : 1 – 10 mV (in steps of 0.5 mV).
Other leads are proportional to Lead II by the following percentages:
Lead I : 60 %
Lead II : 100 %
Lead III : 40 %
V1 : 63 % [ Reference LA ]
V2 : 71 % [ Reference LA ]
V3 : 68 % [ Reference LA ]
V4 : 80 % [ Reference LA ]
V5 : 55 % [ Reference LA ]
V6 : 49 % [ Reference LA ]
Pacer Manufacturer Algorithms
CU Medical, GE, HP, Laerdal, Mindray, Philips, PhysioControl, Schiller, WelchAllyn, Zoll
Pacer Sensitivity Test
Wave form, R WavePolarity Normal and Reversed, selectable
Dynamic Sensitivity0.05mV to 5.00mV in 50µV steps
General Specifications
Dimensions220mm x 150mm x 90mm (L x W x H)
Weight1.5kg
Operation9.6V/2400mAh Nickel Metal Hydride battery pack
Battery charge time2.5 hours
Battery capacity (fully charged)12 hours
Mains supply110/230V AC; 48 to 66Hz, 35VA power supply
Storage environment-15°C to +60°C
Operating conditions0°C to +40°C
Environmental protectionIP 40
CommunicationUSB
Display LCD colour graphic display¼” VGA
Memory100 test results including graphs
Impact rating5J

Downloads

Do you own this product?

Register your UniPulse 400 today to activate your warranty and to stay up to date with the latest product updates, news and support information.


Make an Enquiry
Stay in the know
Sign up to our mailing list today to stay up to date with the latest industry news and information from Rigel.

I'd like to talk to a sales advisor

Our team of sales advisors are on hand to help you with any queries you have about our products.