- Compact, rugged design with large color screen
- Compatible with monophasic, biphasic and pulsed waveforms
- Rechargeable battery allowing operation without the need for mains power
- ECG simulation with high level output
- Reliable and non-inductive defibrillator test load of 50Ω
Available in the US - Call 813 886 2775
The UniPulse 400 is designed to comprehensively test all defibrillators accurately and efficiently. The large vibrant colour screen will display both test results and waveforms in amazing detail. The dedicated fast keys and simple to use operating system enables test engineers to select the relevant test function in seconds.
This comprehensive defibrillator analyzer is capable of analyzing all monophasic, biphasic, standard and pulsating waveforms. This unrivalled functionality and our new comprehensive pacer function makes the UniPulse 400 the ultimate defibrillator analyzer on the market.
The large internal memory and on-board results storage will reduce test time and help work towards a modern paperless system. Download results to "Med-eBase" asset management software via our simple USB function or use the on screen data recall to review results – it's never been so simple.
The ergonomic enclosure of the UniPulse 400 makes the unit compact, rugged and lightweight so you can easily move location with this portable product. Our handy Rigel carry case can fit the unit alongside any additional accessories you may require allowing easy transportation to different sites.
These are just a few of the reasons we believe you'll want to invest in our UniPulse 400. To see for yourself, request a live online demonstration today!
> The complete defibrillator analyzer solution – including pacer functionality.
> Clear and vibrant LCD colour display with simple navigation – including dedicated fast keys. Less button pushing, more testing.
> Rugged, compact and easy to hold – take it anywhere, anytime... easily with battery operation.
> Compatible with all defibrillators – accurately measure and display waveforms from monophasic to biphasic, all in a tester that fits in your hand.
- Pacer functionality
- Compatible with monophasic, biphasic and pulsed waveforms
- Colour LCD display
- Easy and intuitive navigation with dedicated fast test and simulation keys
- Rechargeable battery allowing operation without the need for mains power
- Data download via USB to PC
- Reliable and non-inductive defibrillator test load of 50Ω
- Variable pacer load 50Ω to 1600Ω in 50Ω steps
- ECG simulation with hi-level output
- Multi-lingual firmware to meet requirements across the globe
- Portable, compact and rugged
- Robust carry case to protect your analyzer
- Defibrillator energy discharge
- Charge time
- Cardiac synchronisation
- Over 40 selectable arrhythmias
- Performance waveforms
- 5 pacer modes
Defib - Energy Measurement | |
---|---|
Load Resistance | 50Ω ± 1% non-inductive |
Range | 0 - 199.9 Joules |
Accuracy | ± 1% of reading ± 1 Joule |
Range (High) | 200 - 600 Joules |
Resolution | 0.1 Joules |
Voltage | 0 - 5000 Volts |
Current | 0 - 100 Amps |
Maximum pulse width | 5μs – 120ms |
ECG Simulator | |
---|---|
ECG simulation with hi-level output. |
ECG Waveforms – Ventricular Arrhythmias | |
---|---|
Premature Ventricular Contraction - Intermittent 80 BPM, Amplitude 0.50 - 5.00mV(±2%) | Default Spec Value |
(PVCI) | |
Bigeminy (BIG) | 80 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Trigeminy (TRIG) | 80 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Ventricular Flutter (VFLT) | 240 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Ventricular Fibrillation - Coarse (VFBC) | 240 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Ventricular Fibrillation - Fine (VFBF) | 240 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Monomorphic Ventricular Tachycardia (MVT) | 210 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Right-focal Premature Ventricular Contraction | 80 BPM, Amplitude 0.50 - 5.00mV(±2%) |
ECG Waveforms – Atrial Arrhythmias | |
---|---|
Sinus Arrhythmia (SAR) | 20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Missing Beat (MB) | 20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Atrial Flutter (AFLT) | 300 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Atrial Fibrillation (AFB) | 20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Paroxysmal Atrial Tachycardia (PAT) | 180 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Premature Junctional Contraction (PJC) | 20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%) |
ECG Performance Waveforms | |
---|---|
Sine (SINE) | 0.1 - 300Hz, 1.00 – 10.00mV |
Square (SQ) | 0.1 - 300Hz, 1.00 – 10.00mV |
Triangle (TRI) | 0.1 - 300Hz, 1.00 – 10.00mV |
Sawtooth (SAW) | 0.1 - 300Hz, 1.00 – 10.00mV |
Inverse Sawtooth (INVSAW) | 0.1 - 300Hz, 1.00 – 10.00mV |
Pulse (PULSE) | 0.1 - 300Hz, 0.50 – 5.00mV |
ECG Waveform Output | |
---|---|
Low Level | Low Level |
Hi Level | Output Jack |
Pacer Input | |
---|---|
Fix Load | 50Ω |
Accuracy | +/- 4% + 10µJ |
Over voltage protection | 5000V |
Variable Load | 50 to 1600Ω in 50Ω steps |
Pulse Rate | 5.0 to 800 ppm |
Heart rate selection | 20 – 300 bpm |
Under & overdrive | 85% (20 bpm min) and 115% (300 bpm max) |
Wave form selection | NSR, VFibC, VFibF, MVT, AFib, Missing Beat, R-Wave detection |
Pulse Current Amplitude | 5.00 – 200mA |
Accuracy +/- | (1% rdg +0.02mA) |
Current Measurements | Average (RMS), Leading edge, Trailing edge, Peak (the highest during the pulse) |
Pulse Width | 1.00 - 100ms |
Pulse Energy | 1µJ – 2.00J |
Pacer Refractory Periods | |
---|---|
Refractory Period test | 15 – 500mS (Paced and sensed) |
Accuracy | +/- 1ms |
Pacer Interference Test (Immunity) | |
---|---|
Heart rate | 20-300 bpm |
Frequency | 50 or 60 Hz |
Noise level in mV | 0-15.0mV |
AED Pulse Mode Waveforms | |
---|---|
Normal Sinus Rhythm (NSR) | 20 - 300 BPM, Amplitude 1.00mV(±2%) |
Asystole (ASYS) | |
Ventricular Fibrillation - Coarse (VFBC) | 240 BPM, Amplitude 1.00mV(±2%) |
Ventricular Fibrillation - Fine (VFBF) | 240 BPM, Amplitude 1.00mV(±2%) |
Monomorphic Ventricular Tachycardia (MVT) | 210 BPM, Amplitude 1.00mV(±2%) |
Atrial Fibrillation (AFB) | 20 - 300 BPM, Amplitude 1.00mV(±2%) |
ECG Waveforms - Sinus | |
---|---|
Normal Sinus Rhythm (NSR) | 20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%) |
ST Elevation (STE) | 20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%) |
ST Depression (STD) | 20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Myocardial Infarction (MI) | 20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Tall T (TT) | 20 - 300 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Asystole (ASYS) |
ECG Waveforms – Atrial Conduction Arrhythmias | |
---|---|
First Degree AV Bock (FAVB) | 80 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Second Degree AV Block - Mobitz I (SAVB_MI) | 80 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Second Degree AV Block - Mobitz II (SAVB_MII) | 80 BPM, Amplitude 0.50 - 5.00mV(±2%) |
Third Degree AV Block (TAVB) | 50 BPM, Amplitude 0.50 - 5.00mV(±2%) |
ECG Pacer Waveforms | |
---|---|
Synchronous Atrial (AAI) | 20 - 300 BPM, Pulse amplitude 0.50 – 5.00mV, Pulse width 0.1 – 2.0ms |
Asynchronous Atrial (AOO) | 20 - 300 BPM, Pulse amplitude 0.50 – 5.00mV, Pulse width 0.1 – 2.0ms |
Pacer (PCR) | 20 - 300 BPM, Pulse amplitude 0.50 – 5.00mV, Pulse width 0.1 – 2.0ms |
Ventricular Pacer (VVI) | 20 - 300 BPM, Pulse amplitude 0.50 – 5.00mV, Pulse width 0.1 – 2.0ms |
Atrial & Ventricular Pacer (DDD) | 20 - 300 BPM, Pulse amplitude 0.50 – 5.00mV, Pulse width 0.1 – 2.0ms |
R-Wave Detection (RWD) | 20 - 300 BPM, Pulse amplitude 0.50 – 5.00mV |
ECG Noise Selection | |
---|---|
Amplitude | Default Spec Value0 – 10.00mV |
Frequency | 50 - 60Hz |
ECG Accuracy | |
---|---|
Rate | Default Spec Value± 1% |
Amplitude | ± 2% (LA-LL), ± 10% (Paddles) |
Lead II : 1 – 10 mV (in steps of 0.5 mV). | |
Other leads are proportional to Lead II by the following percentages: | |
Lead I : 60 % | |
Lead II : 100 % | |
Lead III : 40 % | |
V1 : 63 % [ Reference LA ] | |
V2 : 71 % [ Reference LA ] | |
V3 : 68 % [ Reference LA ] | |
V4 : 80 % [ Reference LA ] | |
V5 : 55 % [ Reference LA ] | |
V6 : 49 % [ Reference LA ] |
Pacer Manufacturer Algorithms | |
---|---|
CU Medical, GE, HP, Laerdal, Mindray, Philips, PhysioControl, Schiller, WelchAllyn, Zoll |
Pacer Sensitivity Test | |
---|---|
Wave form, R Wave | Polarity Normal and Reversed, selectable |
Dynamic Sensitivity | 0.05mV to 5.00mV in 50µV steps |
General Specifications | |
---|---|
Dimensions | 220mm x 150mm x 90mm (L x W x H) |
Weight | 1.5kg |
Operation | 9.6V/2400mAh Nickel Metal Hydride battery pack |
Battery charge time | 2.5 hours |
Battery capacity (fully charged) | 12 hours |
Mains supply | 110/230V AC; 48 to 66Hz, 35VA power supply |
Storage environment | -15°C to +60°C |
Operating conditions | 0°C to +40°C |
Environmental protection | IP 40 |
Communication | USB |
Display LCD colour graphic display | ¼” VGA |
Memory | 100 test results including graphs |
Impact rating | 5J |
Register your UniPulse 400 today to activate your warranty and to stay up to date with the latest product updates, news and support information.
Sign up to our Newsletter.
Stay up to date with the latest industry and product news, as well as our free educational content such as webinars and our expert guides.
Close