X
- Compact, robust and portable design
- Ideal for equipment that does not require patient lead testing
- Manual control of fault conditions and tests
- Large colour display with clear read-out
- Tests to a range of international standards including IEC 60601, 62353, 61010 and NFPA-99
- Insulation testing to IEC 62353
- Accurate high current, low energy earth bond testing
The Rigel SafeTest 60 is a robust, reliable and dedicated medical safety analyzer. It is ideal for testing high volumes of medical and laboratory equipment that does not require patient lead testing, such as beds, hoists, infusion pumps, CPAP’s and centrifuges etc.
With a large colour display and a colour-coded user interface, it’s easy to select the required tests with a single key press, whilst a fast step-through of the test routine makes the testing process speedy and dependable.
Whilst small, the SafeTest 60 includes a range of safety tests to enable compliance with a range of international safety standards, including leakage testing to IEC 60601, 62353, 61010 and NFPA-99, earth bond testing to 62353, 61010 and NFPA-99, and insulation testing to IEC 62353.
Full manual control offers the benefit of executing only those specific tests that are required and provide the user with full control of the power cycles, making testing simple, easy and fast.
An automatic warning of secondary earth/ground paths ensures users are made aware when invalid readings are made, thus ensuring correct and accurate test results first time, every time.
The SafeTest 60 is available in a wide range of power configurations to suit local and international markets, and is supplied with a protective carry case as standard.
Earth Continuity | |
---|---|
Method | 2 wire ZAP technique. |
Test Current | >±200mADC into 2Ω |
Max Test Voltage | 4-24Vrms o/c |
Measuring Range (low range) | 0.001 – 0.999Ω / 0.001Ω resolution |
Measuring Range (mid range) | 1.00 – 9.99Ω / 0.01Ω resolution |
Measuring Range (high range) | 10.0 – 19.9Ω / 0.1Ω resolution |
Accuracy | ± 1% of value, ± 5mΩ |
Circuit Protection | Test inhibited if ≥30VAC or DC at 4mm inputs |
Powered Leakage Measurements | |
---|---|
IEC 62353 | Equipment Leakage (Direct) |
IEC / AAMI 60601 | Earth + Enclosure Leakage |
NFPA-99 | Ground + Chassis Leakage |
IEC 61010 | Touch Leakage, Touch Voltage |
Test Voltage | Mains Supply Voltage |
Measuring Range | 0.1μA to 9999μA |
Accuracy | ± 2%, ± 5µA |
Mains Reversal | Softkey |
Single Fault Conditions | Open neutral via softkey Open earth via softkey |
Frequency Response | IEC 60601 - 62353, NFPA-99 and IEC 61010 |
EUT Load Current Measurement | |
---|---|
Range | 0.0A - 20.0A |
Resolution | 0.1A |
Accuracy | ±5% ± 2 digits |
General Specification | |
---|---|
Weight | 1.1kg / 2.5lbs (unit) 2.2kg / 5lbs (complete with accessories) |
Size (L x W x D) | 225 x 150 x 100mm / 9 x 6 x 4" |
Insulation Resistance (Non US versions only) | |
---|---|
Measurement | EUT to Earth |
Voltage | 500VDC @1mA |
Maximum O/C Voltage | <600VDC |
Range | 100K - 20MΩ ± 5% ± 2 digits |
Resolution | 0.01MΩ |
Short circuit current | <2mA |
Voltage Measurement | |
---|---|
Application | L-N, L-E, N-E and touch voltage (IEC 61010) |
Range | 0.0V - 300VAC |
Resolution | 0.1Hz |
Accuracy | ± 2% ± 5 digits (between 10V - 270VAC) |
Mains frequency | 45.0 - 66.0Hz |
Power Source | |
---|---|
Maximum current rating | 20A @ 120V / 16A @ 230V |
Duty cycle | 15A to 20A, 5 min, on/5 min, off 10A to 15A, 7 min, on/3 min, off 0A to 10A, continuous |
Mains Power | 90-264V 46-64Hz |
Standard Accessories (supplied with SafeTest 60) | |
---|---|
Calibration certificate | |
Carrying case | |
Bond test probe with clip | |
Detachable mains cable | |
Electronic instruction manual | |
Quick start guide |